+
  • 3 banner.jpg
  • VU3(1719996542152).jpg

VU3

VU3

VU3

Veterinary Color Doppler Ultrasound System

所属分类:

Portable Color Doppler Ultrasound

 

The VU3 is equipped with a specialized software package, featuring a comprehensive measurement suite for precise diagnostics. Its lightweight design allows for versatility in various scenarios, while offering exceptional imaging quality and a wide range of applications.Overall, theVU3 significantly enhances daily veterinary clinical diagnostics, making it a highly effective professional ultrasound system for veterinarians.

 

 

Professional Vet-specific Presets

 

 

 

Veterinary Applications

 

 

 

 

Probe Model

Probe

Imaging

       8P2MA

       ● 3.5-15.0MHz

       ● Single crystal phased array probe

       ● For Cardiology of felines

       3P2PA

       ● 1.0-6.5MHz

       ● Phased array probe

       ● For Cardiology of big-sized canines

       5P1PA

       ● 2.5-13.0MHz

       ● Phased array probe

       ● For Cardiology of small and medium-sized canines

       6C1PD

       ● 3.5-12.0MHz

       ● Micro convex array probe 

       ● For Abdomen, Cardiology, Reproduction

       3C5PD

       ● 1.0-7.5MHz

       ● Convex array probe

       ● For Abdomen and Reproduction 

       10L2PD

       ● 4.2-16.0MHz

       ● High-frequency linear array probe

       ● For Abdomen and Small Parts

       7L4PD

       ● 4.2-15.0MHz

       ● Linear array probe

       ● For Abdomen and Small Parts

 

 

Dedicated Design for Veterinary

 

 

 

Technologies

 

1

Frequency Composite Imaging

Combine the high penetration of the fundamental frequency and the high resolution of the harmonic frequency to improve the detail resolution and contrast resolution of the near field and the far field to provide the best image quality.

 

 

1

Pulse Inverse Harmonic Imaging PIHI

By removing the fundamental wave signal while maximizing the retention of the second harmonic wave signal, the signal intensity is increased by more than 30% compared to traditional signal processing, reducing noise and artifacts, and improving the contrast resolution of tissue images.

 

 

1

ZClear Adaptive Spatial Filtering

This technology tracks the specific signals of different tissue edges in real time to enhance the edges, while monitoring each pixel to optimize tissue signal, effectively removing noise, and integrating edge information and internal tissue pixel information perfectly.It retains valid signals and restores two dimensional images with real, delicate, and excellent contrast.


 

关键词:

SAF Coolest v1.2 设置面板VYGSA-AQFJ-SSXAE-DSS

修改浏览器滑块样式: 4px,4px,#f00

无数据提示

Sorry,当前栏目暂无内容

您可以查看其他栏目或返回 首页

SVG图标库请自行添加图标,用div包起来,并命名使用